• Key Features:
    Output Rating:
    -Power: 1.5KVA, 3ø (61701); 3KVA, 3ø (61702); 4.5KVA, 3ø (61703); 6KVA, 3ø (61704); 12KVA, 3ø (61705)
    -Voltage: 0-150V/0-300V
    -Frequency: 15~1.2kHz
    -Phase angle: 0~360˚ Programmable
    -Built-in PFC, provides input power factor of over 0.98
    -AC+DC output mode
    -Comprehensive measurement capability,V, Irms, Ipk, Iinrush, P, PF, CF of current etc.
    -Programmable r.m.s. current limit
    -Turn on, turn off phase angle control
    -Full protection: OP, OC, OV and OT protection
    -Optional GPIB and RS-232 interface
    -Advanced PWM technology delivers high power density in a compact rack-mountable package
    -User-definable power-on status
    -Built-in output isolation relays
    -Easy use graphic user interface: softpanel (Option)
    -Optional function for transient voltage output, including LIST, PULSE, STEP ans INTERHARMONICS mode
  • Key Features:
    -Power Rating : 1800W, 3600W, 4500W
    -Voltage Range : 50V ~ 350Vrms
    -Current Range : Up to 18Arms, 36Arms, 45Arms
    -Peak Current : Up to 54A, 108A, 135A
    -Parallel / 3-Phase Function
    -Frequency Range : 45 ~ 440Hz, DC
    -Crest Factor Range : 1.414 ~ 5.0
    -Power Factor Range : 0 ~ 1 lead or lag (Rectified mode)
    -CC, CR, CV, CP for DC Loading
    -Constant & Rectified Load Modes for AC Loading
    -Analog Voltage & Current Monitor
    -Timing Measurement for Battery, UPS, Fuse and Breaker tests
    -Measurement : V, I, PF, CF, P, Q, S, F, R, Ip+/- and THDv
    -Short circuit simulation
    -Full Protection : OC, OP, OT protection and OV alarm
  • Key Features:
    -Built-in PFC, provide input power factor over 0.98 (full load)
    -AC+DC output mode for voltage DC offset simulation
    -Programmable voltage,current limit
    -Comprehensive measurement capability,V, Hz, Irms, Ipk, Iinrush, P, VAR, VA, PF, CF of current and etc.
    -High output current crest factor, ideal for inrush current testing
    -Turn on, turn off phase angle control
    -One-key recall for 9 different voltage and frequency
    -Programmable slew rate setting for changing voltage and frequency
    -Analog input for power amplifier
    -Optional Analog programming interface
    -Optional GPIB and RS-232 interface(Model 61601~61605)
    -Full protection: OP,OC,OV and OT protection
    -Easy use graphic user interface: softpanel (option)
    -Capable of delivering power output up tp 90KVA by implementing Master-Slave operation
  • The 1320 Bias Current Source output can be controlled by LCR Meter Model 3302/3252/11022/ 11025 directly. The 1320S connected externally can output current up to 100A. The bias current scan frequency triggered automatically or manually can analyze the iron core characteristics in inductor for quality inspection and product feature analysis. They are the best measurement instruments combination for inductor test.
  • This system is designed for large DC current testing, up to 300A. The connector between bias current sources is low ESR (This system provides power choke characteristic sweep graph analysis through Windows® base software or sweep function of the meter. The bias current scan triggered automatically or manually can analyze the iron core characteristics in inductor for quality inspection and product feature analysis. The Chroma 11300 is a just right test solution for magnetic choke and core used in various power supply.