| InfiniiVision 1000 X-Series |
InfiniiVision 2000 X-Series |
InfiniiVision 3000G X-Series |
InfiniiVision 4000A/G X-Series |
InfiniiVision 6000 X-Series |
|
| Analog channels | 2 and 4 | 2 and 4 | 2 and 4 | 2 and 4 | 2 or 4 |
| Bandwidth (upgradable) |
50, 70, 100, 200 MHz |
70, 100, 200 MHz | 100, 200, 350, 500 MHz, 1 GHz |
200, 350, 500 MHz, 1 GHz, 1.5 GHz |
16 (MSO models or upgrade) |
| Digital channels | External trigger can be used as a 3rd digital channel for 2 channel model |
8 (MSO models or upgrade) 1 |
16 (MSO models or upgrade) |
16 (MSO models or upgrade) |
1, 2.5, 4, 6 GHz |
| Maximum sample rate |
2 GSa/s | 2 GSa/s | 5 GSa/s | 5 GSa/s | 20 GSa/s |
| Maximum memory depth |
Up to 2 Mpts standard |
1 Mpt/channel | 4 Mpts | 4 Mpts | 4 Mpts |
| Waveform update rate |
Up to 200,000 wfms/sec |
Up to 200,000 wfms/sec |
> 1,000,000 wfms/sec |
> 1,000,000 wfms/sec |
> 450,000 wfms/sec |
| Display | 7-inch display | 8.5-inch display | 8.5-inch capacitive touch display |
12.1-inch capacitive touch display |
12.1-inch, capacitive touch, gesture enabled display |
| Zone touch trigger | No | No | Standard | Standard | Standard |
| Voice Control | No | No | No | No | Standard |
| WaveGen 20-MHz function/ arbitrary waveform generator |
Single-channel function only (standard on G models) |
Single-channel function only (option) |
Single-channel AWG (standard) |
Dual-channel AWG (standard on G models) |
Dual-channel AWG (option) |
| Integrated digital voltmeter (standard) |
Yes | Yes | Yes | Yes | Yes |
| Integrated hardware counter (standard) |
5-digit frequency counter |
5-digit frequency counter (8 digits with external 10 MHz clock reference) |
8-digit frequency counter or totalizer |
5-digit frequency counter |
10-digit frequency, period, or totalizer counter |
| Serial protocol analysis |
I2C, UART (standard on all models) SPI, CAN/LIN (standard on DSO models) |
Yes (optional: CAN, LIN, I²C, SPI, RS232/UART) 1 |
Yes (standard: I2C, SPI, RS232/422/485/ UART, I2S, USB PD, optional: ARINC 429, CAN/CANdbc/ CANFD/ LIN/LIN symbolic, SENT, FlexRay, LIN, MILSTD- 1553, SPI, CXPI, Manchester/NRZ) |
Yes (standard on G models: I2C, SPI, RS232/422/485/ UART, I2S, USB PD, optional: ARINC 429, CAN/CAN-dbc/CANFD/ LIN/LIN symbolic, SENT, FlexRay, LIN, MIL-STD-1553, USB 2.0, CXPI, Manchester/NRZ) |
Yes (optional: I2C, SPI, UART/RS232, CAN/CANdbc/ CANFD/ LIN/LIN symbolic, SENT, FlexRay, I2S, MIL-STD1553, CXPI, ARINC429, USB 2.0, Manchester/NRZ, USB PD) |
| Segmented memory | Standard on DSO model |
Standard | Standard | Standard | Standard |
| Mask/limit testing | Standard on DSO model |
Option | Standard | Standard on G models |
Option |
| Histograms | No | No | Standard | Standard on G models |
Standard |
| Power analysis | No | No | Standard | Option | Option |
| Frequency Response Analysis |
Standard on G models |
No | Standard | Standard on G models |
Option |
| USB 2.0 signal quality test |
No | No | No | Option | Option |
| HDTV analysis | No | No | Standard | Standard on G models |
Option |
| Advanced waveform math |
No | Standard | Standard | Standard | Standard |
| Connectivity | Standard USB 2.0, LAN |
Standard USB 2.0 (LAN/video option) (GPIB option) |
Standard USB2.0 (LAN/video option) (GPIB option) |
Standard USB2.0, LAN, video out (GPIB option) |
Standard USB2.0, LAN, video out (GPIB option) |