Key Features:
-Voltage Ranges:-15/30/60/150/300/600 Vrms/1200Vrms (optional)
-Current Ranges : 0.005/0.02/0.05/0.2/0.3/0.5/2/5/20/30 Arms
-Frequency Range : DC, 10Hz~10kHz
-Embedded high speed DSP, 16 bits Analog/Digital converters withmax samipling rate up to 250kHz
-Capable of meeting the IEC 61000-4-7 harmonics measurement requirements
-Smart Range function provides seamless power integration measurement underauto range mode
-Supports external shunt and CT for higher current applications
-5 mA minimum current range & 0.1mW power resolution
-Meets ENERGY STAR/EN 50564 /IEC 62301/ErP requirements
-User-define criteria provides automatic PASS/FAIL indications
-THD and user-specify order distortion measurement
-Inrush current and energy measurements
-Voltage/ Current harmonics measurements up to 100 orders
-USB (Host) interface provides data logging functionality
-Support GPIB, USB, RS232, LAN (option) interface
-
Key Features:
-Floating Output Design meet EN50191 (19032-P)
-500VA Power Rating (19032-P)
-Five instruments in one: AC Hipot, DC Hipot, Insulation Resistance, Ground Bond and Leakage Current (Option)
-Twin-PortTM function (Patent)
-Programmable output voltage to 5kV AC and 6kV DC
-Insulation resistance to 50GΩ/1000V DC
-Ground bond up to 30A (Option up to 40A / 60A)
-Open/Short check(OSC)
-ARC detection (Flashover)
-Password Protected front panel lockout
-Storage of 50 Tests Setups with 100 Steps per setup
-Optional dynamic leakage current auto scanning (A190305/A190306/A190307/A190308)
-Standard RS-232 Interface
-Standard GB Offset KIT, SCANNER Interface
-Optional GPIB Interface
-Optional Bar-code Scanner
-Optional EST software for test programming, data mining, statistic
-UL, TüV ,CE mark (Model 19032)
-CE mark (Model 19032-P)
A190308
-Plug in to 19032 for Hipot, Line Leakage Auto Scan
-Five Different Kinds Human Body RC Network
-Four measurements mode : Normal, Reverse, Single Fault Normal, Single Fault Reverse
-Up to 20A Line Input Current Capability
-Build in A/D and Calibration Data Memory Easy to Install
-Multiple Display Mode Voltage-LC, Amp-LC, VA-LC
-Earth LC, Enclosure LC, Patient LC and Patient Auxiliary LC Test
-
Key Features:
-Compact size and weight attributable to advance PWM technology
-AC+DC output mode for voltage DC offset simulation
-Programmable output impedance for IEC 61000-3-3
-IEC 61000-4-11, IEC 61000-4-14, IEC 61000-4-28 voltage dips and frequency variation simulation
-Harmonics, interharmonics waveform synthesizer for IEC 61000-4-13 testing
-Power line disturbance simulation capability
-Programmable voltage and current limit settings
-Comprehensive measurement capability, including current harmonics
-High output current crest factor, ideal for inrush current testing
-Turn on, turn off phase angle control
-TTL signal which indicates output transient
-Optional analog programmable interface
-2 units combined in series for high Voltage source (Model 61501~61505)
-3 units combined to 3-phase power output (Model 61501~61505)
-Optional GPIB and RS-232 interface (Model 61501~61505)
-Easy use graphic user interface: softpanel (Option)
-Softpanel for IEC regulation test
-Capable of delivering power output up to 90KVA by implementing Master-slave parallel operation
-
Key Features:
-Rated power: 2kW, 3kW, 4kW, 5kW, 6kW, 12kW, 18kW, 24kW, Max. 240kW (Parallel)
-Voltage range: 0-150V, 0-600V, 0-1200V
-Current range: 2,000A max. per unit
-CC, CR, CV & CP operation modes
-CR+CC, CR+CV, CC+CV complex modes
-Up to 10 units master/slave parallel control
-Dynamic synchronous control in static and dynamic loads
-User defined waveform (UDW)
-CZ mode for turn on capacitive load simulation
-External loading current simulation
-Auto frequency sweep up to 50kHz
-Real time power supply load transient response simulation & Vpk+/- measurement
-User programmable 255 sequential front panel input status
-Ultra high precision voltage & current measurement
-Precision high speed digitizing measurement/data capture
-Voltage, current & Pmax measurement for OCP/OLP tesing
-Timing & discharging measurement for batteries
-Instant overpower loading
-Short circuit simulation
-Smart fan control
-Full protection: OC (adjustable), OT,OP (adjustable) protection & OV warning
-Standard USB, optional Ethernet and GPIB interfaces
-
Key Features:
-500VA output power
-Floating output complies with EN50191
-Corona Discharge Detection (CDD, 19055-C only)
-Flashover Detection
-Breakdown Voltage (BDV) Analysis
-High Frequency Contact Check (HFCC)
-Open Short Check (OSC)
-Ground Fault Interrupt
-Standard RS-232 & HANDLER interface
-Optional GPIB interface
-Key lock when fail
-Programmable voltage & test limit
-Support for the A190301 8HV Scanning Box
FUNCTIONS
Hipot
- AC 5kV/100mA
- DC 6kV/25mA
Insulation
- 5kVmax
- 1MΩ~50GΩ