• Key Features:
    Floating Output Design meet EN50191 (19032-P)
    500VA Power Rating (19032-P)
    Five instruments in one: AC Hipot, DC Hipot, Insulation Resistance, Ground Bond and Leakage Current (Option)
    Twin-PortTM function (Patent)
    Programmable output voltage to 5kV AC and 6kV DC
    Insulation resistance to 50GΩ/1000V DC
    Ground bond up to 30A (Option up to 40A / 60A)
    Open/Short check(OSC)
    ARC detection (Flashover)
    Password Protected front panel lockout
    Storage of 50 Tests Setups with 100 Steps per setup
    Optional dynamic leakage current auto scanning (A190305/A190306/A190307/A190308)
    Standard RS-232 Interface
    Standard GB Offset KIT, SCANNER Interface
    Optional GPIB Interface
    Optional Bar-code Scanner
    Optional EST software for test programming, data mining, statistic
    UL, TüV ,CE mark (Model 19032)
    CE mark (Model 19032-P)
    A190308
    Plug in to 19032 for Hipot, Line Leakage Auto Scan
    Five Different Kinds Human Body RC Network
    Four measurements mode : Normal, Reverse, Single Fault Normal, Single Fault Reverse
    Up to 20A Line Input Current Capability
    Build in A/D and Calibration Data Memory Easy to Install
    Multiple Display Mode Voltage-LC, Amp-LC, VA-LC
    Earth LC, Enclosure LC, Patient LC and Patient Auxiliary LC Test
  • Key Features:
    10 channels in one design
    10 sets of sync output and measurement
    AC/DC/IR 3 in 1 EST test
    Master/Slave link - 10 units max.
    Programmable V-output and limits
    OSC (Open/Short Check)
    Flashover detection
    5kVAC & 6kV DC hipot test
    1MΩ~50GΩ insulation resistance test
    Standard RS232/Handler/GPIB interface
    Large LCD panel
    Key lock function
    CE Mark
  • Key Features:
    10kV AC & 20kV DC withstand voltage test
    0.1MΩ~50GΩ insulation resistance test
    Breakdown Voltage test (BDV)
    Flashover Detection (ARC)
    High Voltage Contact Check (HVCC)
    High Frequency Contact Check (HFCC)
    Open Short Check (OSC)
    Ground Fault Interrupt (GFI) for human protection circuit
    Fast charge/discharge function
    Programmable output & test limit
    Standard USB, RS232 & HANDLER interfaces
    Optional GPIB interface
    CE Mark
  • Key Features:
    500VA output power
    Floating output complies with EN50191
    Corona Discharge Detection (CDD, 19055-C only)
    Flashover Detection
    Breakdown Voltage (BDV) Analysis
    High Frequency Contact Check (HFCC)
    Open Short Check (OSC)
    Ground Fault Interrupt
    Standard RS-232 & HANDLER interface
    Optional GPIB interface
    Key lock when fail
    Programmable voltage & test limit
    Support for the A190301 8HV Scanning Box
    FUNCTIONS
    Hipot
    - AC 5kV/100mA
    - DC 6kV/25mA
    Insulation
    - 5kVmax
    - 1MΩ~50GΩ
  • Key Features:
    3 in 1 Tester : AC, DC, IR
    Programmable output voltage to 5kV AC and 6kV DC
    Trip current programmable to 30mA AC and 10mA DC
    Insulation resistance to 50GΩ/1000V DC
    Built-in 8 channel SCANNER (19053 only)
    Built-in 4 channel SCANNER (19054 only)
    Open/Short Check (OSC)
    Ground Fault Interrupt (GFI)
    ARC detection (Flashover)
    Storage of 50 Tests Setups with 100 Steps per setup
    Optional transformer test fixture (19053 only)
    Standard RS-232 Interface
    Optional GPIB Interface