• Key Features:
    -Floating Output Design meet EN50191 (19032-P)
    -500VA Power Rating (19032-P)
    -Five instruments in one: AC Hipot, DC Hipot, Insulation Resistance, Ground Bond and Leakage Current (Option)
    -Twin-PortTM function (Patent)
    -Programmable output voltage to 5kV AC and 6kV DC
    -Insulation resistance to 50GΩ/1000V DC
    -Ground bond up to 30A (Option up to 40A / 60A)
    -Open/Short check(OSC)
    -ARC detection (Flashover)
    -Password Protected front panel lockout
    -Storage of 50 Tests Setups with 100 Steps per setup
    -Optional dynamic leakage current auto scanning (A190305/A190306/A190307/A190308)
    -Standard RS-232 Interface
    -Standard GB Offset KIT, SCANNER Interface
    -Optional GPIB Interface
    -Optional Bar-code Scanner
    -Optional EST software for test programming, data mining, statistic
    -UL, TüV ,CE mark (Model 19032)
    -CE mark (Model 19032-P)
    A190308
    -Plug in to 19032 for Hipot, Line Leakage Auto Scan
    -Five Different Kinds Human Body RC Network
    -Four measurements mode : Normal, Reverse, Single Fault Normal, Single Fault Reverse
    -Up to 20A Line Input Current Capability
    -Build in A/D and Calibration Data Memory Easy to Install
    -Multiple Display Mode Voltage-LC, Amp-LC, VA-LC
    -Earth LC, Enclosure LC, Patient LC and Patient Auxiliary LC Test
  • Key Features:
    -10 channels in one design
    -10 sets of sync output and measurement
    -AC/DC/IR 3 in 1 EST test
    -Master/Slave link - 10 units max.
    -Programmable V-output and limits
    -OSC (Open/Short Check)
    -Flashover detection
    -5kVAC & 6kV DC hipot test
    -1MΩ~50GΩ insulation resistance test
    -Standard RS232/Handler/GPIB interface
    -Large LCD panel
    -Key lock function
    -CE Mark
  • Key Features:
    -10kV AC & 20kV DC withstand voltage test
    -0.1MΩ~50GΩ insulation resistance test
    -Breakdown Voltage test (BDV)
    -Flashover Detection (ARC)
    -High Voltage Contact Check (HVCC)
    -High Frequency Contact Check (HFCC)
    -Open Short Check (OSC)
    -Ground Fault Interrupt (GFI) for human protection circuit
    -Fast charge/discharge function
    -Programmable output & test limit
    -Standard USB, RS232 & HANDLER interfaces
    -Optional GPIB interface
    -CE Mark
  • Key Features:
    -500VA output power
    -Floating output complies with EN50191
    -Corona Discharge Detection (CDD, 19055-C only)
    -Flashover Detection
    -Breakdown Voltage (BDV) Analysis
    -High Frequency Contact Check (HFCC)
    -Open Short Check (OSC)
    -Ground Fault Interrupt
    -Standard RS-232 & HANDLER interface
    -Optional GPIB interface
    -Key lock when fail
    -Programmable voltage & test limit
    -Support for the A190301 8HV Scanning Box
    FUNCTIONS
    Hipot
    - AC 5kV/100mA
    - DC 6kV/25mA
    Insulation
    - 5kVmax
    - 1MΩ~50GΩ
  • Key Features:
    -3 in 1 Tester : AC, DC, IR
    -Programmable output voltage to 5kV AC and 6kV DC
    -Trip current programmable to 30mA AC and 10mA DC
    -Insulation resistance to 50GΩ/1000V DC
    -Built-in 8 channel SCANNER (19053 only)
    -Built-in 4 channel SCANNER (19054 only)
    -Open/Short Check (OSC)
    -Ground Fault Interrupt (GFI)
    -ARC detection (Flashover)
    -Storage of 50 Tests Setups with 100 Steps per setup
    -Optional transformer test fixture (19053 only)
    -Standard RS-232 Interface
    -Optional GPIB Interface