Key Features:
Floating Output Design meet EN50191 (19032-P)
500VA Power Rating (19032-P)
Five instruments in one: AC Hipot, DC Hipot, Insulation Resistance, Ground Bond and Leakage Current (Option)
Twin-PortTM function (Patent)
Programmable output voltage to 5kV AC and 6kV DC
Insulation resistance to 50GΩ/1000V DC
Ground bond up to 30A (Option up to 40A / 60A)
Open/Short check(OSC)
ARC detection (Flashover)
Password Protected front panel lockout
Storage of 50 Tests Setups with 100 Steps per setup
Optional dynamic leakage current auto scanning (A190305/A190306/A190307/A190308)
Standard RS-232 Interface
Standard GB Offset KIT, SCANNER Interface
Optional GPIB Interface
Optional Bar-code Scanner
Optional EST software for test programming, data mining, statistic
UL, TüV ,CE mark (Model 19032)
CE mark (Model 19032-P)
A190308
Plug in to 19032 for Hipot, Line Leakage Auto Scan
Five Different Kinds Human Body RC Network
Four measurements mode : Normal, Reverse, Single Fault Normal, Single Fault Reverse
Up to 20A Line Input Current Capability
Build in A/D and Calibration Data Memory Easy to Install
Multiple Display Mode Voltage-LC, Amp-LC, VA-LC
Earth LC, Enclosure LC, Patient LC and Patient Auxiliary LC Test
-
Key Features:
10 channels in one design
10 sets of sync output and measurement
AC/DC/IR 3 in 1 EST test
Master/Slave link - 10 units max.
Programmable V-output and limits
OSC (Open/Short Check)
Flashover detection
5kVAC & 6kV DC hipot test
1MΩ~50GΩ insulation resistance test
Standard RS232/Handler/GPIB interface
Large LCD panel
Key lock function
CE Mark
-
Key Features:
10kV AC & 20kV DC withstand voltage test
0.1MΩ~50GΩ insulation resistance test
Breakdown Voltage test (BDV)
Flashover Detection (ARC)
High Voltage Contact Check (HVCC)
High Frequency Contact Check (HFCC)
Open Short Check (OSC)
Ground Fault Interrupt (GFI) for human protection circuit
Fast charge/discharge function
Programmable output & test limit
Standard USB, RS232 & HANDLER interfaces
Optional GPIB interface
CE Mark
-
Key Features:
500VA output power
Floating output complies with EN50191
Corona Discharge Detection (CDD, 19055-C only)
Flashover Detection
Breakdown Voltage (BDV) Analysis
High Frequency Contact Check (HFCC)
Open Short Check (OSC)
Ground Fault Interrupt
Standard RS-232 & HANDLER interface
Optional GPIB interface
Key lock when fail
Programmable voltage & test limit
Support for the A190301 8HV Scanning Box
FUNCTIONS
Hipot
- AC 5kV/100mA
- DC 6kV/25mA
Insulation
- 5kVmax
- 1MΩ~50GΩ
-
Key Features:
3 in 1 Tester : AC, DC, IR
Programmable output voltage to 5kV AC and 6kV DC
Trip current programmable to 30mA AC and 10mA DC
Insulation resistance to 50GΩ/1000V DC
Built-in 8 channel SCANNER (19053 only)
Built-in 4 channel SCANNER (19054 only)
Open/Short Check (OSC)
Ground Fault Interrupt (GFI)
ARC detection (Flashover)
Storage of 50 Tests Setups with 100 Steps per setup
Optional transformer test fixture (19053 only)
Standard RS-232 Interface
Optional GPIB Interface